Problem/Issue 4715
 
Query for PDR ID
Example: search for PDR ID 109-9999 , just enter 9999 into the entry field and press ENTER.
Open Build: Open Date: Language:
1.70.267 30.11.2001 (All)
Closed Build: Close Date: Platform:
1.70.276 14.12.2001 WIN32
State: Reference PDR ID: Hotfix Rollup No.:
CLOSED    
Symptom:
XbpPresSpace:setPageSize() returns invalid unit identifier
Description:
Method :setPageSize() of the XbpPresSpace class returns an invalid unit
identifier. After changing page units to "GRA_PU_ARBITRARY", for example,
calling :setPageSize() would not return the value defined for
"GRA_PU_ARBITRARY". Instead, return would be the value defined plus two.
In this example, this would be the value 6.



Solution:
Problem has been solved. Download the fix here. This issue does not
exist in future versions.

If this is not applicable,
then substract the value 2 from the page size identifier returned by
:setPageSize().







 
(C) Copyright Alaska Software Inc. 2008, All rights reserved!
Disclaimer, Limitation of Liability, no Warranty: THE INFORMATION, DOCUMENTS, FILES AND MATERIALS CONTAINED IN THIS SITE ARE PROVIDED "AS IS". ALASKA SOFTWARE DOES NOT WARRANT THE ACCURACY, ADEQUACY OR COMPLETENESS OF THIS INFORMATION AND MATERIALS; THUS EXPRESSLY DISCLAIMS LIABILITY FOR ERRORS OR OMISSIONS IN THIS INFORMATION AND MATERIALS.