Symptom:
ODBCDBE behaves wrong in writing to a field of datatype W
Description:
When writing a string into a field of the datatype W (=nChar) via
the ODBCDBE (can be done on MSSQL for example) the content will be
added with CHR(0) 4 times before starting to fill the fields with
CHR(32) = spaces.



Solution:
REPLACE field->typeW with PADR(cString,len(field->typeW))



 
(C) Copyright Alaska Software Inc. 2008, All rights reserved!
Disclaimer, Limitation of Liability, no Warranty: THE INFORMATION, DOCUMENTS, FILES AND MATERIALS CONTAINED IN THIS SITE ARE PROVIDED "AS IS". ALASKA SOFTWARE DOES NOT WARRANT THE ACCURACY, ADEQUACY OR COMPLETENESS OF THIS INFORMATION AND MATERIALS; THUS EXPRESSLY DISCLAIMS LIABILITY FOR ERRORS OR OMISSIONS IN THIS INFORMATION AND MATERIALS.